40 C.F.R. § 455.23

Current through October 31, 2024
Section 455.23 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT)

Except as provided in 40 CFR 125.30 through 125.32 , any existing point source subject to this subpart must achieve the effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology: The limitations for BOD, TSS and pH are the same as those specified in 40 CFR 455.22 .

BCT Effluent Limitations

Effluent Limitations

Pollutant or pollutant property Maximum for any one day** Average of daily values shall not exceed**
BOD57.4001.6000
TSS6.1001.8000
pH**

* Within the range 6.0 to 9.0

** Metric units: Kilogram pollutant/1,000 kg of total organic active ingredients.

English units: Pound pollutant/1,000 lb of total organic active ingredients

40 C.F.R. §455.23

58 FR 50689, Sept. 28, 1993