N.2. Starting Load Test. - A system starting load test may be conducted by applying rated voltage and 0.5-ampere load.
T.2. Load Test Tolerances. - The tolerances for EVSE load tests shall be as shown in Table T.2. Accuracy Classes and Tolerances for EVSE.
Table T.2.
Accuracy Classes and Tolerances for EVSE
Accuracy Class | Application or Commodity Being Measured | Acceptance Tolerance | Maintenance Tolerance |
2.0 | AC electricity as a vehicle fuel | 1.0 % | 2.0 % |
5.01 | DC electricity as a vehicle fuel | 2.5 % | 5.0 % |
2.02 | DC electricity as a vehicle fuel | 1.0 % | 2.0 % |
1 The tolerance values for Accuracy Class 5.0 DC EVSE are applicable to devices installed prior to January 1, 2033.
2 The tolerance values for Accuracy Class 2.0 DC EVSE are applicable to devices installed on or after January 1, 2033.
Appendix D. Definitions
electricity as vehicle fuel. - Electrical energy transferred to or stored onboard an electric vehicle primarily for the purpose of propulsion. [3.40]
Cal. Code Regs. Tit. 4, § 4002.11
Note: Authority cited: Sections 12027 and 12107, Business and Professions Code. Reference: Sections 12107 and 13400, Business and Professions Code.