Cal. Code Regs. tit. 25 § 1262

Current through Register 2024 Notice Reg. No. 50, December 13, 2024
Section 1262 - Vent Location and Support

All vent pipes in outdoor locations shall be located at least ten (10) feet from an adjoining property line and shall extend at least ten (10) feet above ground level. All vent pipes shall be supported by at least the equivalent of a four (4) inch by four (4) inch nominal dimension redwood post securely anchored in the ground. One-piece galvanized iron vent pipes may be self-supporting if securely anchored at their base in concrete at least twelve (12) inches in depth and extending a minimum four (4) inches out from the pipe.

Cal. Code Regs. Tit. 25, § 1262

1. Amendment of section heading and section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).

Note: Authority cited: Section 18300, Health and Safety Code. Reference: Section 18630, Health and Safety Code.

1. Amendment of section heading and section filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).