Appendix - APPENDIX

Current through April 27, 2019
Appendix - APPENDIX

The appendix included herein is taken from the State of Wyoming Occupational Health and Safety Rules and Regulations for Oil and Gas Well Servicing. They are inserted for informational purposes, and are enforceable under such rules and regulations, as well as those similar requirements found in the Rules and Regulations for oil and Gas Well Drilling of the State of Wyoming.

Section 4. Wind Guys.

a. Four ( 4) crown-to-ground guys of at lease 5/8" diameter, 6x37 class, improved plow steel or steel of higher breaking strength shall be used on every rig up.

b. Two (2) racking boards-to-ground guys of a least 9/16' diameter,, 6x37 class, improved plow steel or steel of greater breaking strenght shall be used in every rig up where tubing is in the board.

c. A thorough inspection of all wind guy anchor lines in use shall be made at least once a year, and a full written, dated and signed report of wind guy anchor lines' conditions kept on file where readily available for inspection by division personnel. One copy shall be kept in the service unit. All inspections shall be performed by a competent person authorized by the employer to perform such inspection. Wire ropes with any of the following defects shall be removed from service as wind guy anchor lines:

(1) When three broken wires are found in one lay of 6 by 6 wire rope;

(2) When six broken wires are found in one lay of 6 by 19 wire rope;

(3) When nine broken wires are found in one lay of 6 by 37 wire rope;

(4) When eight broken wires are found in one lay of 8 by 19 wire rope;

(5) When wire ropes not described herein are found to have four percent ( 4%) of the total number of wires composing such wire broken in one lay;

(6) When marked corrosion appears;

(7) When corroded or broken wires at end connection are noted;

(8) When end connections are corroded, cracked, bent, worn or improperly applied; or

(9) When evidence of kinking, crushing, cutting or unstranding are noted.

d. All chains, boomers, clamps, and tensioning devices remaining in the working guy-lines shall be bypassed by continuing the guy-line through or around the anchor, then back to the guy-line again. The guy-line shall be properly secured with at least three (3) U-bolt clamps of proper size, or their equivalent.

e. Guy-line anchors, including expanding anchors, pipe anchors, concrete anchors, or other approved techniques shall be used, except that temporary, moveable or driven stakes shall not be used. Locations of all anchors shall be marked with an appropriate marker that extends a minimum of twenty-four inches (24") above ground level.

f. Anchor placement and pull tests.

(1) With respect to anchors installed, reinstalled or relocated on or before September 1 4, 1970 anchors shall be proof-tested along an angle that approximates the wind guys working plane within the anniversary or 12th month prior to use of the anchors. EXAMPLE: An anchor pull tested in January 1992 shall be usable through the last day of January 1993, likewise an anchor tested on June 10, 199 4 is good through June 30, 199 5. Such tests will be made at the poundage determined by the anchor's location (per Figure 5a) within Sector A, B or C, and computed according to the appropriate sector curve on Figure 4a. If either of the two front anchors fall in a sector which requires. a higher test pull, both front anchors shall be tested as if they were located in the sector requiring the higher pull test. If ground is frozen at the time of the test and anchors are to be used again when the ground is not frozedn, the anchors must be retested before use. If any anchor is more than three feet (3') above or below the well ground level, Figure 6 shall be used to determine the adjusted distance for which the pull test requirement will be established using Figure 4a. Anchors to be used for singles derricks only shall be proof-tested to 10,000 lbs. and must be located within Sector A, B or C of Figure 5a.

(2) With respect to anchors installed, reinstalled or relocated on or before Septembaer 25, 1970 anchors shall be proof-tested along an angle that approximates the wind guys working plane within the anniversary or 12th month prior to use of the anchors. EXAMPLE: An anchor pull tested in January 1992 shall be usable through the last day of January 1993, likewise an anchor tested on June 10, 1994 is good through June 30, 1995. Such tests will be made at the poundage determined by the anchor's location (per Figure 5b) within Sector A, B or C, and computed according to the appropriate sector curve on Figure 4a. If any anchor falls in a sector which requires a higher test pull, all four (4) anchors shall be tested as if they were located in the sector requiring the higher pull test. If ground is frozen at the time of the test and anchors are to be used again when the ground is not frozen, the anchors must be retested before use. If any anchor is more than three feet (31 ) above or below the well ground level, Figure 6 shall be used to determine the adjusted distance for which the pull test requirement will be established using Figure 4a. Anchors to be used for singles derricks only shall be proof-tested on 10,000 lbs. and must be located within Sector A, B or C of Figure 5b.

9- No oil or gas well servicing unit shall be rigged up on a work site unless wind guy anchors have been installed and tested in accordance with this section.

h. Wind guy anchors and servicing unit placement.

(1) Wind guy anchors shall be positioned in accordance with Figure Sa or 5b.

(2) The well operator shall provide a visible marker in such a positoin that a straight line through the marker and through the well head will form an angle with a line through any anchor and the well head which complies with the minimum angle requirements as follows:

Each Sector

Ouadrant

Minimum Ancile

A

(20')

35"

B

(30")

30"

C

(45' )

22.5 0

*Minimum Angle Distances From Well Centerline Front and

Rear

Sides

14

10

17

10

24

10

* In the use of Figure 5b, if any-anchor in the pattern falls within Sector "C", the minimum angle on all Tnchors is 22.50. One or more anchors located in Sector "B", with TFe_ remaining anchors in Sector "A" requires the minimum angle to be 300 on all anchors. In the use of Figure 5a, the minimum angle of any anchor is =.50. A field determination of the minimum angle can be found by measuring these distances in convenient units such as feet, yards or paces in reference to the well centerline, the anchors and the longitudinal axis of the unit. (Example: With a single anchor in the pattern located in Sector "C", one could take 24 paces from the well head on an imaginary line which bisects the two adjacent anchors between which the servicing unit will be placed. At this point there would be placed a marker or a stake. He would then take 10 paces to the left and turn so he was aligned with the well head. If anchors "A" and "C" (Diagram A) are `outsi@el'his alignment, these anchors would be satisfactory. Going back to the center marker, he would repeat this procedure to the right. If anchors "B" and "D" are outside his alignment, the center marker is satisfactory. If alignment to either the left or right was not satisfactory, the center marker or stake would be moved to the left or right as needed and the alignment rechecked until the center marker is located properly.) -

(a) The visible marker shall be placed on a direct line from the well head which passes through the center marker at least 100 feet from the well.

(3) The servicing unit operator shall center his unit in line with the marker and the well head. .

(4) Where there is provided a readily' visible and clearly defined pad for the positioning of the servicing unit which will maintain the required minimum angle from the longitudinal axis of the unit and the well to any anchor, the use of the marker. in h.(2) is optional.

i. Each well site shall have available at such well site in an accessible weather-proof container an Anchor Record. Such Anchor Record shall state whether the anchor was installed prior or subsequent to September 24, 1970, the date of any relocation or reinstallation of any anchor at the well site after September 24, 1970, each anchor's pull test (sector) from Figure 5a or 5b, and the date, total amount of such pull test, and identification of the tester.

(1) Each anchor shall be pulled and held for a period of two

(2) minutes after all movement (creep) has stopped.

(2) The anchor record shall state "FOR SINGLES DERRICKS ONLY" if the anchors are only tested to Ten Thousand pounds (10,000#).

CLARIFICATION OF SECTIONS 4. f. and 4. i.:

Individual anchors installed, reinstalled or relocated prior to September 25, 1970 @iill be tested in accordance with Section 4. f.(1) and Figure 5a. Individual anchors installed, reinstalled or relocated September 25, 1970 or later,-will be installed and tested in accordance with Section 4. f.(2) and Figure 5b. This means that the installation of a single anchor subsequent to September 25, 1970 would not require the remaining anchors at the same well site to be tested and installed according to Section 4.f.(2) and Figure 5b, until such anchor(s) has been installed, reinstalled or relocated.

If there is any doubt that individual anchors were installed before September 25, 1970, such anchor's rec-orcT will indicate this information, and will be tested in accordance with Section 4.f.(2) and Figure 5b. ANCHOR ELEVATION ADJUSTMENT CHART

Directions for use of Figure 6:

After determining the elevation difference between the well ground level and the anchor ground, level, find that difference on the Figure designated "Anchor Elevation Above or Below Well Ground Level". Follow that difference line until it meets the vertical line which represents the actual distance from well head to the anchor. Then follow the slanted line, either up or down as applicable, until "O" (Well Ground Level) is reached. Read vertically, and read the "Horizontal Distance from Well - Feet". This adjusted distance is then applied to Figure 4 to determine the required pull test according to the Sector in which the anchor is located. (Example: An anchor located 10" above well ground level 1001 from the well head would, using Figure 6, require the same pull test as though it was 110' from the well. An anchor 15' below well ground level 80' from the well head would require the same pull test as though it was 70' from the well head.)

j. All anchor testing units shall be certified by the Wyoming Occupational Health and Safety Department.

k. Wind guys from crown or tubing (racking) board shall not be any closer than ten feet (101) from powerlines, and in no case shall a wind guy be extended above or below a powerline.;

1. Employers shall not erect any doubles derricks on anchors prooftested for singles derricks.

n. Gin Pole operations shall be performed in accordance with Chapter XIV, Section 5. , Wyoming Occupational Health and Safety Rules and Regulations (General).