S.C. Code Regs. § 61-58.5.O

Current through Register Vol. 48, No. 07, July 26, 2024
Section 61-58.5.O - VOC Monitoring, Sampling and Analytical Requirements
(1) This section shall apply to community and non-transient non-community water systems.
(2) Beginning with the initial compliance period analysis of the contaminants listed in Section N(2) above, for the purpose of determining compliance with the maximum contaminant level shall be conducted as follows:
(a) Groundwater systems shall take a minimum of one (1) sample at every entry point to the distribution system which is representative of each well after treatment (hereafter called a sampling point). Each sample must be taken at the same sampling point unless conditions make another sampling point more representative of each source or treatment plant.
(b) Surface water systems (or combined surface/ground) shall take a minimum of one (1) sample at points in the distribution system that are representative of each source or at each entry point to the distribution system after treatment (hereafter called a sampling point). Each sample must be taken at the same sampling point unless conditions make another sampling point more representative of each source, treatment plant, or within the distribution system.
(c) If the system draws water from more than one (1) source and the sources are combined before distribution, the system must sample at an entry point to the distribution system during periods of normal operating conditions (i.e., when water representative of all sources is being used).
(d) Each community and non-transient non-community water system shall take four consecutive quarterly samples for each contaminant listed in Section N(2)(b) through (u) above, during each compliance period beginning in the initial compliance period.
(e) If the initial monitoring for contaminants listed in Section N(2)(a) through (h) and the monitoring for the contaminants listed in Section N(2)(i) through (u) as allowed in paragraph (2)(r) of this section, has been completed by December 31, 1992, and the system did not detect any contaminant listed in Section N(2) above, then each ground and surface water system shall take one (1) sample annually beginning with the initial compliance period.
(f) After a minimum of three (3) years of annual sampling, the Department may allow groundwater systems with no previous detection of any contaminant listed in Section N(2) above, to take one (1) sample during each compliance period.
(g) Each community and non-transient non-community ground water system which does not detect a contaminant listed in Section N(2) above, may apply to the Department for a waiver from the requirement of paragraphs (4)(e) and (4)(f) of this section after completing the initial monitoring. (For the purposes of this section, detection is defined as 0.0005 mg/l.) A waiver shall be effective for no more than six (6) years (two compliance periods). The Department may also issue waivers to small systems for the initial round of monitoring for 1,2,4-trichlorobenzene.
(h) The Department may grant a waiver after evaluating the following factor(s):
(i) Knowledge of previous use (including transport, storage, or disposal) of the contaminant within the watershed or zone of influence of the system. If a determination by the Department reveals no previous use of the contaminant within the watershed or zone of influence, a waiver may be granted.
(ii) If previous use of the contaminant is unknown or it has been used previously, then the following factors shall be used to determine whether a waiver is granted.
(A) Previous analytical results.
(B) The proximity of the system to a potential point or non-point source of contamination. Point sources include spills and leaks of chemicals at or near a water treatment facility or at manufacturing, distribution, or storage facilities, or from hazardous and municipal waste landfills and other waste handling or treatment facilities.
(C) The environmental persistence and transport of the contaminants.
(D) The number of persons served by the public water system and the proximity of a smaller system to a larger system.
(E) How well the water source is protected against contamination such as whether it is a surface or groundwater system. Groundwater systems must consider factors such as depth of the well, the type of soil, and wellhead protection. Surface water systems must consider watershed protection.
(i) As a condition of the waiver a groundwater system must take one (1) sample at each sampling point during the time the waiver is effective (i.e., one sample during two compliance periods or six years) and update its vulnerability assessment considering the factors listed in paragraph (2)(h) of this section. Based on this vulnerability assessment the Department must reconfirm that the system is non-vulnerable. If the Department does not make this reconfirmation within three (3) years of the initial determination, then the waiver is invalidated and the system is required to sample annually as specified in paragraph (e) of this section.
(j) Each community and non-transient non-community surface water system which does not detect a contaminant listed in Section N(2) above may apply to the Department for a waiver from the requirements of paragraph (4)(e) of this section after completing the initial monitoring. Composite samples from a maximum of five sampling points are allowed, provided that the detection limit of the method used for analysis is less than one-fifth of the MCL. Systems meeting this criteria must be determined by the Department to be non-vulnerable based upon a vulnerability assessment during each compliance period. Each system receiving a waiver shall sample at the frequency specified by the Department (if any).
(k) If a contaminant listed in Section N (2)(b) through (u) above, is detected at a level exceeding 0.0005 mg/l in any sample, then:
(l) Systems which violate the requirements of Section N(2) above, as determined by paragraph (2)(o) of this section must monitor quarterly. After a minimum of four (4) consecutive quarterly samples which shows the system is in compliance as specified in paragraph (2)(o) of this section, the system and the Department determines that the system is reliably and consistently below the maximum contaminant level, the system may monitor at the frequency and time specified in paragraph (4)(k)(iii) of this section.
(m) The Department may require a confirmation sample for positive or negative results. If a confirmation sample is required by the Department, the result must be averaged with the first sampling result and the average is used for the compliance determination as specified by paragraph (2)(o) of this section. The Department has the discretion to delete results of obvious sampling errors from this calculation.
(n) The Department may reduce the total number of samples a system must analyze by allowing the use of compositing. Composite samples from a maximum of five sampling points are allowed, provided that the detection limit of the method used for analysis is less than one-fifth of the MCL. Compositing of samples must be done in the laboratory and analyzed within fourteen (14) days of sample collection.
(i) If the concentration in the composite sample is 0.0005 mg/l for any contaminant listed in Section N(2) above, then a follow-up sample must be taken within fourteen (14) days at each sampling point included in the composite, and be analyzed for that contaminant.
(ii) If duplicates of the original sample taken from each sampling point used in the composite are available, the system may use these instead of resampling. The duplicate must be analyzed and the results reported to the Department within fourteen (14) days of collection.
(iii) If the population served by the system is greater than 3,300 persons, then compositing may only be permitted by the State at sampling points within a single system. In systems serving 3,300 persons, the Department may permit compositing among different systems provided the 5-sample limit is maintained.
(iv) Compositing samples prior to GC analysis.
(A) Add 5 ml or equal larger amounts of each sample (up to 5 samples are allowed) to a 25 ml glass syringe. Special precautions must be made to maintain zero headspace in the syringe.
(B) The samples must be cooled at 4°C during this step to minimize volatilization losses.
(C) Mix well and draw out a 5-ml aliquot for analysis.
(D) Follow sample introduction, purging, and desorption steps described in the method.
(E) If less than five samples are used for compositing, a proportionately small syringe may be used.
(v) Compositing samples prior to GC/MS analysis.
(A) Inject 5-ml or equal larger amounts of each aqueous sample (up to 5 samples are allowed) into a 25-ml purging device using the sample introduction technique described in the method.
(B) The total volume of the sample in the purging device must be 25 ml.
(C) Purge and desorb as described in the method.
(o) Compliance with Section N(2) above, shall be determined based on the analytical results obtained at each sampling point. If one sampling point is in violation of an MCL, the system is in violation of the MCL.
(i) For systems monitoring more than once per year, compliance with the mcl is determined by a running annual average at each sampling point.
(ii) Systems monitoring annually or less frequently whose sample result exceeds the MCL must begin quarterly sampling. The system will not be considered in violation of the MCL until it has completed one year of quarterly sampling.
(iii) If any sample result will cause the running annual average to exceed the MCL at any sampling point, the system is out of compliance with the MCL immediately.
(iv) If a system fails to collect the required number of samples, compliance will be based on the total number of samples collected.
(v) If a sample result is less than the detection limit, zero will be used to calculate the annual average.
(p) Analysis for the contaminants listed in Section N(2) above, shall be conducted using EPA-approved methods listed in 40 CFR 141.
(q) Analysis under this section shall only be conducted by laboratories that are certified by the Department.
(r) The Department may allow the use of monitoring data collected after January 1, 1988, for purposes of initial monitoring compliance. If the data are generally consistent with the other requirements in this section, the Department may use those data (i.e., a single sample rather than four quarterly samples) to satisfy the initial monitoring requirement of paragraph (2)(d) of this section. Systems which use grandfathered samples and did not detect any contaminant listed in Section N(2)(b) through (u) above shall begin monitoring annually in accordance with paragraph (2)(e) of this section beginning with the initial compliance period.
(s) The Department may increase required monitoring where necessary to detect variations within the system.
(t) Each public water system shall monitor at the time designated by the Department within each compliance period.
(u) All new systems or systems that use a new source of water that begin operation after January 22, 2004 must demonstrate compliance with the MCL within a period of time specified by the Department. The system must also comply with the initial sampling frequencies specified by the Department to ensure a system can demonstrate compliance with the MCL. Routine and increased monitoring frequencies shall be conducted in accordance with the requirements in this section.
(3) If a community or a non-transient non-community water system fails to comply with an applicable VOC MCL, that system shall give notice to the customers served by the system in accordance with the requirements of R.61-58.6.E.

S.C. Code Regs. 61-58.5.O