Or. Admin. R. 333-121-0360

Current through Register Vol. 63, No. 8, August 1, 2024
Section 333-121-0360 - Pool Water Purity
(1) Pool water purification system must be run sufficiently to maintain the conductivity of the pool water below 20 microsiemens per centimeter under normal circumstances. If pool water conductivity rises above 20 microsiemens per centimeter, the licensee shall take prompt actions to lower the pool water conductivity and shall take corrective actions to prevent future recurrences.
(2) The licensee shall measure the pool water conductivity frequently enough, but no less than weekly, to assure that the conductivity remains below 20 microsiemens per centimeter. Conductivity meters must be calibrated at least annually.

Or. Admin. R. 333-121-0360

PH 5-2005, f. & cert. ef. 4-11-05

Stat. Auth.: ORS 453.675

Stats. Implemented: ORS 453.675