Current through Register No. 44, October 31, 2024
Section Env-Dw 305.28 - Final Report: Contents The applicant shall provide the following pursuant to Env-Dw 305.26(c)(2):
(a) A description of the pumping test, including: (1) All of the data collected;(2) A description of how each pumping test requirement in the approved preliminary report was met;(3) A graph developed using the following methodology:a. Water level data shall be plotted as a semi-logarithmic plot of drawdown versus elapsed time, expressed in minutes elapsed since pumping began, presented on the logarithmic axis; andb. A straight line shall be: 1. Drawn through the data on the semi-logarithmic plot with a slope based on the data points from the end of the pumping period; and2. Used to extrapolate the drawdown for a time of 180 days, or 259,200 minutes, which shall be the theoretical 180-day drawdown; and(4) If an alternate pumping test method was approved in the preliminary report, all data and analyses as approved in the preliminary report and the justification for the alternative method required by Env-Dw 305.14(a)(2);(b) A description of the water quality sampling program, with specific note of any deviations from the program as approved in the preliminary reports, and copies of all laboratory results;(c) A description of the method used to refine the wellhead protection area;(d) Updated contamination source and water use inventories;(e) A description of the contamination risk control program with supporting evaluations and documentation;(f) A description of the wellhead protection program, including: (1) The name, title, mailing address, daytime telephone number, and email address, if any, of the person who is or will be responsible for implementing the wellhead protection program; and(2) A copy of or reference to the education materials;(g) A copy of the well completion report prepared in accordance with We 800;(h) A proposed permitted production volume and a description of the means by which it was established in accordance with Env-Dw 305.20;(i) An estimate of the effect pumping the permitted production volume from the well will have on: (1) Water levels in private and public wells within 1,000 feet of the production well;(2) Water levels in nearby surface waters and wetlands;(3) Existing groundwater contamination plumes; and(4) Saltwater intrusion into the freshwater aquifer;(j) A vulnerability assessment of potential impacts to the well from natural hazards, if necessary based on: (1) The site's location relative to surrounding topographic and hydrologic features that pose a reasonable threat to the facility's structural integrity or functionality, or both; or(2) The well location's history of impacts by natural hazards; and(k) Documentation of legal control of the sanitary protective area.N.H. Admin. Code § Env-Dw 305.28
Adopted by, Volume XXXVI Number 14, Filed April 7, 2016, Proposed by #11062, Effective 4/1/2016, Expires 4/1/2026.