Minn. R. agency 120, ch. 7601, HOPPER SCALES, pt. 7601.5000

Current through Register Vol. 49, No. 17, October 21, 2024
Part 7601.5000 - HOPPER SCALES
Subpart 1.Capacity.

For a hopper scale, the load capacity of the hopper must be at least 80 percent of the capacity of the weight indicator. Load capacity must be determined by using the highest density material that will normally be weighed in the hopper.

Subp. 2.Dust-control systems.

Weighing accuracy of a hopper scale system must not be affected by air flow or by a fluctuation or differential in air pressure caused by a dust-control system. If scale accuracy can be affected by adjusting dampers or flow-control devices in the dust-control system, the dampers and devices must be sealed with a Minnesota seal to prevent adjustment.

Minn. R. agency 120, ch. 7601, HOPPER SCALES, pt. 7601.5000

20 SR 1928

Statutory Authority: MS s 239.06