La. Admin. Code tit. 43 § XI-1923

Current through Register Vol. 50, No. 9, September 20, 2024
Section XI-1923 - Internal Corrosion Control
A. No operator may transport any carbon dioxide that, with substances mixed in it, would corrode the pipe or other components of its pipeline system, unless it has investigated the corrosive effect of the mixture on the system and has taken adequate steps to mitigate corrosion.
B. If corrosion inhibitors are used to mitigate internal corrosion the operator shall use inhibitors in sufficient quantity to protect the entire part of the system that the inhibitors are designed to protect and shall also use coupons or other monitoring equipment to determine their effectiveness.
C. The operator shall, at intervals not exceeding seven and one-half months, but at least twice each calendar year, examine coupons or other types of monitoring equipment to determine the effectiveness of the inhibitors or the extent of any corrosion.
D. Whenever any pipe is removed from the pipeline for any reason, the operator must inspect the internal surface for evidence of corrosion. If the pipe is generally corroded such that the remaining wall thickness is less than the minimum thickness required by the pipe specification tolerances, the operator shall investigate adjacent pipe to determine the extent of the corrosion. The corroded pipe must be replaced with pipe that meets the requirements of this regulation or, based on the actual remaining wall thickness, the operating pressure must be reduced to be commensurate with the limits on operating pressure specified in this Part.

La. Admin. Code tit. 43, § XI-1923

Promulgated by the Department of Natural Resources, Office of Conservation, LR 12:115 (February 1986).
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:4(C)(17).