Strike Section P3008.1 of the International Residential Code in its entirety and insert a new Section P3008.1 into the Residential Code in its place to read as follows:
General. Where plumbing fixtures are installed on a floor with a finished floor elevation below the elevation of the manhole cover of the next upstream manhole in the public sewer , such fixtures :
Exception: Where the code official deems it appropriate for the protection of existing multi- level one- and two- family dwellings in flood prone areas, the retrofitting of backwater valves to be installed in the building drain or in a horizontal branch serving fixtures on a floor with a finished elevation above the adjacent manhole in the public sewer be allowed, thereby allowing such fixtures to discharge through the backwater valve.
Strike Section P3008.5 of the International Residential Code in its entirety and insert a new Section P3008.5 into the Residential Code in its place to read as follows:
Location. Backwater valves shall be installed so that access is provided to the working parts for service and repair. Valve access covers shall be watertight.
D.C. Mun. Regs. tit. 12, r. 12-B3008