521 Mass. Reg. 26.1

Current through Register 1527, August 2, 2024
Section 26.1 - GENERAL

All doors and openings along accessible routes shall comply with the following requirements.

26.1.1 Gates, including ticket gates, shall also comply with 521 CMR 26.00.

Exceptions: Openings greater than 24 inches (24" = 6110mm) in depth are not doorways but may be part of an accessible route, in which case they shall comply with 521 CMR 20.00: ACCESSIBLE ROUTES and 521 CMR 24.00: RAMPS (SeeFig. 26a). Doors not requiring full user passage, such as shallow closets, may have the clear opening reduced to 20 inches (20" = 508mm) minimum, See521 CMR 9.5.8, Closets.

Click to view image

26.1.2 In buildings classified in the assembly use and educational use (See780 CMR 302.0) with an occupancy of over 150 (See521 CMR 14.1.1), all required egress doors which lead directly to the outside at grade, shall be made accessible at the exterior as well as the interior so as to provide a safe path of travel to a public way for persons who are disabled. Such egress doors shall be provided with illuminated signage identifying accessibility by the use of the international symbol contained within the "exit" sign (See521 CMR 41.1.3)

521 CMR 26.1