The luminous intensity of a deceleration lamp with the bulbs operated at mean spherical candela and tested as specified in Article 4 of this subchapter shall meet the photometric requirements in Table III after the sample has been mechanically tested in the order shown in Section 733.
TABLE III. PHOTOMETRIC REQUIREMENTS FOR DECELERATION SIGNAL LAMPS
Test point coordinates | Cd | ||
Vertical | Horizontal | Max | Min |
10L | 70 | 25 | |
10U | V | 200 | 60 |
10R | 70 | 25 | |
20L | 40 | 15 | |
10L | 200 | 60 | |
5L | 600 | 200 | |
5U | V | 800 | 350 |
5R | 600 | 200 | |
10R | 200 | 60 | |
20R | 40 | 15 | |
20L | 40 | 15 | |
10L | 200 | 60 | |
5L | 800 | 350 | |
H | V | 1,300 | 600 |
5R | 800 | 350 | |
10R | 200 | 60 | |
20R | 40 | 15 | |
20L | 40 | 15 | |
10L | 200 | 60 | |
5L | 600 | 200 | |
5D | V | 800 | 350 |
5R | 600 | 200 | |
10R | 200 | 60 | |
20R | 40 | 15 | |
10L | 70 | 25 | |
10D | V | 200 | 60 |
10R | 70 | 25 |
Cal. Code Regs. Tit. 13, § 736
Note: Authority cited: Section 26103, Vehicle Code. Reference: Sections 24012 and 26103, Vehicle Code.