456 Neb. Admin. Code, ch. 5, § 001

Current through September 17, 2024
Section 456-5-001 - PLANS

Plans submitted shall meet the following minimum standards:

001.01. Plans may be made on sheets with minimum dimensions of 21 inches by 30 inches or maximum dimensions of 24 inches by 36 inches. Drawings must be of such clarity and with distinct characters of such size as to retain clarity and resolution when reduced to one-half size. Characters and significant figures should not be smaller than one-eighth inch on the original plan. If the applicant desires to submit its plans in an electronic format and/or in dimensions other than described previously in this paragraph, it may do so only if granted permission by the Department in advance.
001.02. Plans must include a detailed description of each proposed well, setting forth the intended depth, screen type and casing size, and pump capacity. All pipelines, pumping stations, treatment plants, location of use, location of injection wells or discharge, and other facilities must be depicted.
001.03. Plans must also include a summary of geologic and hydrologic data.

456 Neb. Admin. Code, ch. 5, § 001

Amended effective 6/27/2022