521 CMR, § 10.8

Current through Register 1533, October 25, 2024
Section 10.8 - LAUNDRY FACILITIES

If laundry facilities are provided in Multiple dwellings, then equivalent, accessible laundry facilities shall be provided.

10.8.1 Location: Laundry facilities shall be on an accessible level and on an accessible route.
10.8.2 At least one washing machine and at least one clothes dryer shall be front loading, shall have a side hinged door, and shall be located so that the door can be opened 180°. See Fig. 10a.

Click to view image

10.8.3 Where laundry work space, such as a folding table, is provided, it shall comply with 521 CMR 35.00: TABLES AND SEATING.
10.8.4 Controls, including the payment mechanism, shall fall within the zone of reach as defined in 521 CMR 5.00: DEFINITIONS.

521 CMR, § 10.8