From Casetext: Smarter Legal Research

Commonwealth v. Cochran

Appeals Court of Massachusetts. Middlesex
Jan 12, 1988
517 N.E.2d 498 (Mass. App. Ct. 1988)

Opinion

No. 87-548.

November 17, 1987.

January 12, 1988.

Present: KASS, CUTTER, WARNER, JJ.

Evidence, Breathalyzer test, Competency, Cross-examination. Motor Vehicle, Operating under the influence.

At the trial of a complaint for operating a motor vehicle while under the influence of intoxicating liquor, the judge erred in denying the defendant's motion to strike the results of a breathalyzer test, where, as a simulator test of the breathalyzer instrument clearly showed, the Commonwealth could not carry its burden of showing that the device had been working properly when the defendant was tested. [264-265]

COMPLAINT received and sworn to in the Cambridge Division of the District Court Department on March 11, 1986.

In the jury session of that division the case was tried before Neil J. Walker, J.

Bruce T. Macdonald for the defendant.

David R. Marks, Assistant District Attorney, for the Commonwealth.


Among the items of evidence placed before the jury of six which convicted William Cochran of driving under the influence of intoxicating liquor (G.L.c. 90, § 24 [ a][1]), were the results of a breathalyzer test which placed Cochran at the outer limits of drunkenness. Cochran's primary contention on appeal is that the breathalyzer test results should not have been received in evidence because, demonstrably, the test device was malfunctioning. We think the point is a sound one and reverse the conviction.

Being under the influence of intoxicating liquor connotes a less disabled state than drunkenness, i.e., one may transgress the statute without being drunk. See Commonwealth v. Griffin, 19 Mass. App. Ct. 174, 183 n. 8 (1985).

These are the facts the jury could have found. On March 10, 1986, the defendant, Cochran, precipitated a three-car collision by slamming into the rear of a car stopped at a red light. That car was propelled, in turn, into the car in front of it. Nobody was seriously injured, but the defendant demonstrated a certain incapacity of speech, gait, and thought. His reactions to the accident were passive and detached. By reason of the defendant's conduct, his physical unsteadiness, his withdrawn attitude, and the smell of alcohol on his breath, the driver of the car struck by the defendant's vehicle and a passerby concluded that the defendant was quite drunk.

Such was also the conclusion of Officer DeFrancesco of the Cambridge police. DeFrancesco, who knew the defendant reasonably well, and, more to the point, knew him sober, thought the occasion called for field sobriety tests. Cochran could not walk a straight line but did prove able to recite the alphabet.

Although the field sobriety tests had not been devastating to Cochran, Officer DeFrancesco thought what he had observed of the defendant warranted placing him under arrest. He was taken to the Cambridge police station and booked. There, duly advised of his rights regarding chemical testing, Cochran elected to submit to a blood alcohol examination. See G.L.c. 90, § 24(1)( e), as amended through St. 1980, c. 383, § 1. Austin Maxwell, a Cambridge police officer trained to administer breathalyzer tests, fed two samples of the defendant's exhalations into a Smith Wesson Breathalyzer, model 2000. Those samples registered an alcohol level at 24 and .25, respectively, a stunning result considering that a reading of .10 or higher triggers a statutory presumption of intoxication. G.L.c. 90, § 24(1)( e), as amended by St. 1980, c. 383, § 1. The defendant waived his right to an independent alcohol level blood test.

In addition to describing the incriminating results which Cochran's two breath samples produced, Officer Maxwell testified about how the breathalyzer device worked, what standard operating procedures were to be followed (e.g., purging the machine before causing it to inhale a new breath sample), and how he had faithfully followed those procedures. Maxwell described, among other things, that following each test of a subject, the operator fed a control sample into the machine. This was called the simulator test.

Cross-examination of Maxwell produced the following exchange:

MR. MACDONALD: "What's the importance of the simulator test?"

OFFICER MAXWELL: "To verify that the machine is working."

(. . .)

MR. MACDONALD: "What kind of simulator reading would it take for you to see in order to realize the machine wasn't operating properly?"

OFFICER MAXWELL: "Something more than one-thousandths off the .15."

MR. MACDONALD: "So it's your testimony that if the reading on the simulator is . . . less than a .14 or greater than a .16, that would indicate the machine is not operating properly?"

OFFICER MAXWELL: "That's correct."

MR. MACDONALD: "Do you happen to know what the simulator reading was in this case?" (. . .)

OFFICER MAXWELL: "It was .13."

MR. MACDONALD: "Did you notice that at the time?"

OFFICER MAXWELL: "No, I didn't." (. . .)

MR. MACDONALD: "If you had notice ( sic) the .13 at the time of Mr. Cochran's test, would you have rejected the test result and moved to some other way to measure his breath alcohol?"

OFFICER MAXWELL: "Yes, I would have."

Thereupon defense counsel moved to strike the test results. The motion was denied. Earlier the defendant had moved in limine to exclude the breath test because of the simulator deviation.

Extensive discussion of the legal and scientific underpinnings of breathalyzers appears in: Commonwealth v. Brooks, 366 Mass. 423 (1974); Commonwealth v. Bernier, 366 Mass. 717 (1975); Commonwealth v. Neal, 392 Mass. 1 (1984); and Commonwealth v. Doyle, 392 Mass. 23 (1984). Those opinions rest the use of breathalyzer test evidence on an assumption of scientific reliability; i.e., "scientific instruments that measure blood alcohol content on the basis of breath samples" are generally accepted, Commonwealth v. Neal, 392 Mass. at 17, by those, e.g., a community of scientists, who would be expected to be familiar with its use. See Commonwealth v. Fatalo, 346 Mass. 266, 269 (1963); Commonwealth v. Vitello, 376 Mass. 426, 441-442 (1978); Commonwealth v. Whynaught, 377 Mass. 14, 17 (1979).

Implicit in the assumption of reliability is that the device is working properly. That is why breathalyzers come with simulator test ampules and courts have relied on the simulator test as establishing that the device is functioning accurately. See Commonwealth v. Neal, 392 Mass. at 13; Commonwealth v. Doyle, 392 Mass. at 26. The Commonwealth has the burden of proving that a check of accuracy has been run on the breath measuring instrument. As burdens go, it is light. The simulator ampule contains a "breath sample" that should produce a .15 reading. A deviation of .01, plus or minus, is permissible. Guidelines circulated by the State Department of Public Safety to local police departments instruct operators to use another instrument or an alternative method of alcohol level testing whenever a simulator test falls outside the acceptable deviation of plus or minus .01.

Guidelines, Infrared Breath Testing Program (Massachusetts Department of Public Safety). See also Mann Murphy, Infrared Breath Testing Operator's Manual (Massachusetts Department of Public Safety).

Indeed, the Department of Public Safety promulgated a regulation effective July 1, 1987 (too late for this defendant), which invalidates breath tests if the reading of the simulator solution exceeds the plus or minus .01 deviation.

The trial occurred on October 20 (motions only), October 24, and October 27, 1986.

See 501 Code Mass. Regs. § 2.56 (1987), the text of which reads as follows: "(2) A test shall not be considered valid if the defendant fails to supply two adequate breath samples upon request (in which [case] it shall be deemed a refusal under 501 CMR 2.52), if the reading on the calibration standard analysis does not agree with the known value of the simulator solution to within +/- 0.01 blood alcohol content units, or if the readings on the two subject analyses do not agree to within +/- 0.02 blood alcohol content units. In the case of an invalid test that results from something other than the defendant's failure to supply an adequate breath sample or otherwise to comply with any reasonable request by a certified operator that is necessary for the conduct of a breath test, the defendant shall be given an opportunity to consent to a new breath test."

On the test performed on Cochran, it will be recalled, the simulator registered .13, a deviation of minus .02 and beyond the permissible tolerance. The officer who performed the test conceded that he would have rejected the test had he noticed the discrepancy. We are of opinion that the results of breath measuring tests ought not to be received in evidence unless the Commonwealth has adduced evidence through the simulator or similar control mechanism that the measuring device was working. The recent decision in Commonwealth v. Yameen, 401 Mass. 331, 336 (1987), is not to the contrary. There police witnesses, while conceding some departure from test procedures, said that a breathalyzer test had been adequately administered and that the test results were accurate. In the circumstances, any deviation from preferred procedure went to the weight to be accorded the test results and was for the jury to consider. Similarly, had the Commonwealth in this case adduced evidence that the test device was functioning properly and had the defense adduced evidence that it was not, resolution of the conflicting evidence would have been for the jury.

Our view is consistent with that adopted by a majority of jurisdictions which have considered the question. See Moore v. State, 442 So.2d 164, 167 (Ala.Cr.App. 1983) (as a predicate for admitting test results, government must show that instrument used in conducting the test was in good working condition); State v. Rolison, 733 P.2d 326, 329 (Haw.Ct.App. 1987) (in order to have test result of intoxilyzer admitted in evidence, State must lay foundation showing instrument was in proper working order); State v. Geinzer, 406 N.W.2d 457, 458-459 (Iowa Ct.App. 1987) (blood alcohol test inadmissible when testing device registered reading of .01 during "air blank" step rather than .00); State v. Fairleigh, 490 So.2d 490, 497 (La.Ct.App. 1986) (State has obligation of showing that it has strictly complied with all officially promulgated procedures to insure integrity and reliability of chemical test result); State v. Deimeke, 500 S.W.2d 257, 259 (Mo.Ct.App. 1973) (where breathalyzer test was given to defendant between date when machine was found to be functioning properly and date when it was found to be malfunctioning, result is inadmissible); Moser v. North Dakota, 369 N.W.2d 650, 656 (N.D. 1985) (police officer's failure to start breathalyzer device at zero rendered breath sample inadmissible); State v. Hall, 39 Ohio App.2d 87, 89 (1973) (prerequisite for admitting blood alcohol results is showing that breathalyzer equipment was in proper working order). But see State v. Watkins, 104 N.M. 561, 564 (1986), and State v. Johnson, 717 S.W.2d 298, 305 (Tenn.Crim.App. 1986) (any inaccuracies in particular blood alcohol test go to weight, not to the admissibility of evidence).

Although there was other potent evidence of Cochran's intoxication, we cannot say that failure to strike the breathalyzer test results was harmless error. That test was quantitative and it had the seal of scientific approval. Compared to other evidence, the test was likely to be thought the most powerful. It was not merely cumulative. Compare Commonwealth v. Lowe, 391 Mass. 97, 106 (1984).

We are not persuaded by the argument that if the simulator reads on the low side of the standard .15, the defendant has an advantage because his breath readings will be comparably lower than the reality. See, e.g., State v. Shuping, 312 N.C. 421, 430 (1984). Nothing in the record supports such an equivalence and we are not prepared to assume it.

Having thus disposed of the case, it is not necessary to consider the defendant's grievance that he was deprived of permissible cross-examination of Walton, the passerby witness. In the context of the over-all cross-examination, the restraints imposed by the judge did not constitute reversible error. We do think, however, should the case be tried again and should Walton again testify that the defendant's breath smelled of gin or vodka, rather than beer, that the defense is entitled to test by cross-examination what basis Walton has for sniffing that distinction. Compare Commonwealth v. Flynn, 362 Mass. 455, 470 (1972); Commonwealth v. Key, 381 Mass. 19, 29 (1980), and Commonwealth v. Perreault, 13 Mass. App. Ct. 1072, 1075 (1982), with Commonwealth v. Franklin, 366 Mass. 284, 289-290 (1974), and cases cited. See also Commonwealth v. Bookman, 10 Mass. App. Ct. 891, 891-892 (1980).

Judgment reversed. Verdict set aside.


Summaries of

Commonwealth v. Cochran

Appeals Court of Massachusetts. Middlesex
Jan 12, 1988
517 N.E.2d 498 (Mass. App. Ct. 1988)
Case details for

Commonwealth v. Cochran

Case Details

Full title:COMMONWEALTH vs. WILLIAM COCHRAN

Court:Appeals Court of Massachusetts. Middlesex

Date published: Jan 12, 1988

Citations

517 N.E.2d 498 (Mass. App. Ct. 1988)
517 N.E.2d 498

Citing Cases

Commonwealth v. Kelley

The simulator solution, when run through the testing device, should produce a reading of .15. If it produces…

Davila-Lynch v. City of Brockton

The statutory term "under the influence" as used in the drunk driving laws "connotes a less disabled state…